Inner Liner
Extruded virgin seamless smooth bore PTFE (Teflon®)
Outer Cover
The reinforcement braid serves as the outer cover
Reinforcement
One braid (-3 to -12) and two braid (-16)
Application
Medium pressure non-contaminating hose for use with a broad range of chemical resistance. It is inert to most commercial chemicals/acids/alcohols/coolants/elastomers/petroleum products/solvents/vinyls/synthetic lubricants/hydraulic fluids/steam and compressed air. Not suitable for cold and hot (including steam) cycling as can cause the tube to crack. Inner liner is non-conductive - do not use with high velocity fluids and gases. A conductive tubed PTFE hose product is necessary.
Materials and Specifications
Features
Specifications/Performance
Minimum bend radius quoted is based on static applications - for dynamic applications multiply the bend radius by 1.25. Meets or exceeds the performance specification of SAE 100R14A.
Notes
Use of an internal support coil for hoses -6 and larger is recommended for tube support where continuous or extended service at high temperature together with low or negative pressure is expected.
Material
304 grade stainless steel
Temperature Range
-54 degrees C up to +230 degrees C
Safety Factor
4:1
Vacuum Rating
-0.9 Bar (26.7 in.-Hg) -3 to -12, -0.4 Bar (12 in-Hg) -16
Item | ID - inch | ID - mm | OD avg mm | Max WP bar | Max WP - psi | Min Bend Radius mm | Weight - Kgm | Notes |
---|---|---|---|---|---|---|---|---|
STH-03 | 42430 | 4.9 | 7.6 | 206 | 2988 | 50 | 0.09 | |
STH-04 | 44652 | 6.4 | 9.5 | 206 | 2988 | 75 | 0.12 | |
STH-05 | 42491 | 7.9 | 10.9 | 172 | 2495 | 100 | 0.15 | |
STH-06 | 44776 | 9.5 | 12.8 | 138 | 2002 | 125 | 0.18 | Use of an internal support coil for hoses -06 and larger is recommended for tube support where continuous or extended service at high temperature together with low or negative pressure is expected. |
STH-08 | 44593 | 12.7 | 16.3 | 120 | 1740 | 165 | 0.24 | Use of an internal support coil for hoses -06 and larger is recommended for tube support where continuous or extended service at high temperature together with low or negative pressure is expected. |
STH-10 | 44778 | 15.9 | 19.2 | 103 | 1494 | 187 | 0.27 | Use of an internal support coil for hoses -06 and larger is recommended for tube support where continuous or extended service at high temperature together with low or negative pressure is expected. |
STH-12 | 44654 | 19.1 | 22.6 | 69 | 1001 | 212 | 0.35 | Use of an internal support coil for hoses -06 and larger is recommended for tube support where continuous or extended service at high temperature together with low or negative pressure is expected. |
STH-16 | 1 | 25.4 | 30.9 | 69 | 1001 | 225 | 0.44 | Use of an internal support coil for hoses -06 and larger is recommended for tube support where continuous or extended service at high temperature together with low or negative pressure is expected. |
Hose Size | Crimp | Crimp Interlock | Field Attachable | Push-On | Low Pressure Tail |
---|---|---|---|---|---|
-03 | T | ||||
-04 | T | ||||
-05 | T | ||||
-06 | T | ||||
-08 | T | ||||
-10 | T | ||||
-12 | T | ||||
-16 | T |